e)
When the Mark signal is detected, M1108 = ON. The Y0 pulse output will pause during
the ramp down process.
f)
Y0,Y2 relative parameters for Mask and Alignment Mark function:
Parameter
Output
Mark flag
Input
points
Ramp
down
time
Pulse number
for masking
output
Pulse number
for ramp-down
of Mark function
Output pause
(ramp down)
Pause
status
Y0
M1156
X4
D1348 D1026, D1027 D1232, D1233
M1108
M1538
Y2
M1158
X6
D1349 D1135, D1136 D1234, D1235
M1110
M1540
g)
Program example 1:
M0
Y0
M0
M1000
I401
SET
M1156
DMOV K10000 D1232
DPLSR K100000 K1000000
K20
FEND
INCP
D0
IRET
END
When M0 is triggered, Y0 executes the pulse output. If an external interrupt is
detected on X4, the pulse output will execute the ramp down process for 10,000
pulses and then stop. M1108 will be ON to indicate the pause status (ramp down). If
no interrupt is detected, Y0 pulse output will stop after 1,000,000 pulses are
completed.
When the pulse output ramps down and stops after the Mark is detected, M1538 will
be ON to indicate the pause status. If the remaining pulses need to be completed, set
the M1108 flag OFF and the pulse output will resume.
.
4.
Operation of the Mask function on Y0:
Содержание ELC-PB
Страница 1: ......
Страница 5: ...For more information visit www eaton com MN05003003E iv...
Страница 29: ...ELC Programming Manual For more information visit www eaton com MN05003003E 1 24 MEMO...
Страница 502: ...3 Instruction Set MN05003003E For more information visit www eaton com 3 333...
Страница 601: ...ELC Programming Manual For more information visit www eaton com MN05003003E 3 432...
Страница 625: ...ELC Programming Manual For more information visit www eaton com MN05003003E 3 456...