background image

Item no.: 3100 00 14

VBD 549-2 (05.21)

ReWiSo 2696

Instruction manual for the electrical connection and for commissioning

EN

Summary of Contents for 2696

Page 1: ...Item no 3100 00 14 VBD 549 2 05 21 ReWiSo 2696 Instruction manual for the electrical connection and for commissioning EN...

Page 2: ...s well Damage resulting from non compliance with this manual and the safety instructions will void the warranty We assume no liability for any consequential damage Key to symbols i Danger of fatal ele...

Page 3: ...t angle 27 7 Saving the basic settings 27 Safety instructions for automatic and alarm functions 28 Installation and commissioning 29 Installation of the weather station and connection of the drive 30...

Page 4: ...ooting on the controller may only be carried out by a qualified electrician according to VDE 0100 Proceed as follows to commission the controller 1 Carry out the mechanical installation and electrical...

Page 5: ...function u Retraction of sun shading below a preselected outdoor temperature frost protection only in automatic mode u Retraction of sun shading above a preselected wind velocity wind alarm function c...

Page 6: ...l as the operating mode automatic or manual the battery charge state and current alarm message for rain or wind The weather data is refreshed once a minute and when a button is pressed Outdoor tempera...

Page 7: ...netian blinds are retracted manual operation is blocked The wind alarm function can be activated and deactivated in the automatic settings e g for indoor awnings Display of brightness and wind velocit...

Page 8: ...ng stops the drive If the rain or wind alarm is active manual operation is blocked Manual Automatic The button switches back and forth between automatic mode display and manual mode display If the con...

Page 9: ...delay C Retraction delay D Indoor temperature lock E Outdoor temperature lock F Wind alarm G Rain alarm H Memory Calling up the automatic settings Press the SET button in the weather data display for...

Page 10: ...ssing the button The changes made to the values are then not saved If no button is pressed in the automatic settings for 5 minutes the display automatically switches back to the temperature display Ch...

Page 11: ...th a cloudless sky at midday The default setting for the brightness is 40 kLux Adjust the value with higher and lower or select off to deactivate the function If is selected no control by brightness t...

Page 12: ...ings continuously for 1 minute before the sun shading is extended The sun shading therefore reacts quickly to sun Adjust the value with higher and lower Then press SET to proceed to the setting of the...

Page 13: ...the heat of the sun to achieve the desired room temperature e g in the winter energy saving function The sun shading only extends in the sunshine when the value is exceeded The indoor temperature lock...

Page 14: ...ture has already risen to quite high values Ask your conservatory builder for the temperature limit for your sun shading If your sun shading can still operate even at low temperature or if it is insta...

Page 15: ...these 5 minutes the holding time starts again The following table see next section contains reference values for setting the wind alarm Depending on the location of the conservatory and the installat...

Page 16: ...like storm 28 5 32 6 102 3 117 3 11 56 63 Hurricane 32 6 117 3 12 63 F Wind alarm After setting the wind alarm now select whether or not the rain alarm is to be activated The rain alarm protects outd...

Page 17: ...omatic settings Save is displayed to prompt saving of the entered settings H Saving the automatic settings Press the SET button to save your inputs and return to the weather data display Press to exit...

Page 18: ...and automatic data 6 Sun shading position 7 Save Calling up the basic settings PresstheSETbuttonintheweatherdatadisplayforatleast3seconds to call up the automatic settings You are in the automatic set...

Page 19: ...nges made to the settings are then not saved If no button is pressed in the basic settings for 5 minutes the display automatically switches back to the temperature display Changes to settings are agai...

Page 20: ...T button When you have confirmed Learn with the SET button the radio symbol stops flashing and the radio waves are animated they run Now press the orange programming button inside the weather station...

Page 21: ...sun shading slightly Test the two arrow buttons and check on the display whether the sun shading retracts i e opens again with or with u Open the sun shading with the button then press the button to s...

Page 22: ...ng direction of the sun shading You can test the setting directly using the arrow buttons Press the button to switch between the displayed symbols Select If the awning or Venetian blind extends from t...

Page 23: ...r the connected drive ends either after 4 minutes or it is maintained continuously as long as the alarm message is present Press the button to switch between the OFF and ON displays Select If the trav...

Page 24: ...F and ON displays Select In order not to send weather data and automatic commands setting for normal awning and Venetian blind controllers Press the SET button to proceed to the next setting step 5 Tr...

Page 25: ...the desired step with the button Continue to skip the setting of the sun shading position The sun shading is then always fully extended closed in automatic mode In this case continue as described in...

Page 26: ...blind so that it provides no sun shading Then press the SET button to proceed to the next step The prompt Close appears 6 2 Setting the desired position Now extend the sun shading as far as it is lat...

Page 27: ...ading position At the end of the input of the basic settings Save is displayed to prompt you to save the entered settings 7 Saving the basic settings i Press the SET button to save your inputs and ret...

Page 28: ...ions are maintained even if the controller is in manual mode If cleaning or maintenance work has to be carried out in the vicinity of the awning s or Venetian blind s the controller weather station mu...

Page 29: ...t it immediately for possible mechanical damage If transport damage is discovered please notify the supplier immediately A damaged controller must not be put into operation If it is suspected that saf...

Page 30: ...rmit proper wind measurement and to prevent the weather station being covered by snow in winter The weather station must be installed on a vertical wall or mast and aligned horizontally in the transve...

Page 31: ...sensor is latched at the lower edge on the left and right see Fig Remove the cover from the weather station Proceed carefully to avoid tearing off the cable connection between the PCB in the lower se...

Page 32: ...ors with a power consumption higher than 1000 watts must be operated via a relay or contactor with a separate mains lead 1 Cable connection to the precipitation sensor in the housing cover 2 Drive con...

Page 33: ...age on the left and right with an audible click Installation of the weather station and connection of the drive Installation of the weather station Push the housing into the installed bracket from abo...

Page 34: ...or this is located in the lower half of the operating unit For the same reason the operating unit should not be installed above a radiator Ensure that direct draughts from windows or doors do not fals...

Page 35: ...cribed in the section Inserting batteries u The display of the operating unit shows that no radio connection between the weather station and operating unit has been taught in Commissioning u Hold the...

Page 36: ...er the opaque glass cover of the weather station If the brightness is not sufficient illuminate the weather station from above using a powerful torch until a value is displayed Checking the wind senso...

Page 37: ...activated in the automatic settings this is the default setting on delivery see also the section G Rain alarm Note that the umbrella symbol remains displayed for 5 minutes after drying the sensor Che...

Page 38: ...witch off or remove the fuse for cleaning and maintenance Operating unit Clean the display when necessary using a damp cloth Inserting batteries operating unit The battery compartment is inside the ho...

Page 39: ...Procedure Replace the batteries as described in the section Inserting batteries Error and the radio symbol are shown on the display Cause No radio connection between the operating unit and weather sta...

Page 40: ...or in the operating unit is defective Procedure The error may only be remedied by a qualified electrician Please contact your installer Error instead of the brightness or instead of the wind velocity...

Page 41: ...oftware version of the controller weather station Display 10 means version 1 0 12 means 1 2 etc Exit the service data display by pressing the SET button again The following default settings are stored...

Page 42: ...e batteries AA Mignon LR6 Ambient temperature 10 C to 50 C Relative humidity max 80 avoid condensation Weather station Operating voltage 230 V 50 Hz Ambient temperature 30 C to 60 C Dimensions of weat...

Page 43: ...n between the operating unit and weather station is done by radio Weather station connection diagram s Up t Down Mains lead 230 V 50 Hz L N PE Connecting lead to the sun shading e g Venetian blind or...

Page 44: ...44 EN All dimensions in mm technical deviations possible View of the rear panel and weather station drilling pattern Dimensions in mm i...

Page 45: ...45 EN All dimensions in mm technical deviations possible View of the rear panel and operating unit drilling pattern Dimensions in mm i...

Page 46: ...ading above an indoor temperature more than C Outdoor temperature lock below C Wind alarm above m s Rain alarm Yes No Personal setting data for automatic mode i Simplified EU declaration of conformity...

Page 47: ...47 EN Warranty terms and conditions You can find information about the warranty conditions of our products on our homepage i...

Page 48: ...RADEMACHER Ger te Elektronik GmbH Buschkamp 7 46414 Rhede Germany Subject to technical modifications misprints and errors Illustrations not binding...

Reviews: