E L C P r o g r a m m i n g M a n u a l
F or more info rmat io n vi sit: www.e a to n.c om M N 0 5 003 00 3 E
3-448
API Mnemonic
Operands
Function
191
D PPMR
S
1
, S
2
, S, D
2-Axis Relative Point to Point Motion
Bit Devices
Word devices
Program Steps
Type
OP
X Y M S K H KnX
KnY
KnM KnS T
C D E
F
S
1
*
*
*
S
2
*
*
*
S
*
*
*
D
*
DPPMR: 17 steps
ELC ELCB
ELCM
PB PC/PA/PH
PV
PB PH/PA
32 16
P
32 16
P
32 16
P
32 16 P 32 16 P
Operands:
S
1
: Number of output pulses for the X axis
S
2
: Number of output pulses for the Y axis
S
: Max.
point to point output frequency
D
: Pulse output address
Description: (ELC-PV)
1.
This instructin only supports “pulse + direction” mode.
2.
S
1
and
S
2
are the designated number of output pulses in the X axis (Y0 or Y4) and Y axis (Y2
or Y6). The range of these values is -2,147,483,648 ~ +2,147,483,647 (+/- represents the
forward/reverse directions). When in the forward direction, the present value registers are:
CH0 (D1337 high word, D1336 low word), CH1 (D1339 high word, D1338 low word), CH2
(D1376 high word, D1375 low word) and CH3 (D1378 high word, D1377 low word) and they
will increase. When in the reverse direction, the present value will decrease.
3.
D
can use Y0 and Y4.
When Y0 is used:
Y0 refers to the 1
st
group of X-axis pulse outputs.
Y1 refers to 1
st
group of the X-axis direction signal.
Y2 refers to 1
st
group of Y-axis pulse outputs.
Y3 refers to 1
st
group of the Y-axis direction signal.
Y4 refers to 2
nd
group of X-axis pulse outputs.
Y5 refers to 2
nd
group of the X-axis direction signal.
Y6 refers to 2
nd
group of Y-axis pulse outputs.
Y7 refers to 2
nd
group of the Y axis direction signal.
When the instruction execution is complete, the direction signal output will not turn off until the
conditions driving the instruction go false.
D1340/D1379 are the start/end frequencies of the 2-axis of motion. D1343/D1381 are the
times for the first acceleration segment and last deceleration segment of the 2-axis of motion.
The time shall be longer than 10ms. If the time is shorter than 10ms or longer than 10,000ms,
the output will be operated at 10ms. Default setting = 100ms.
4.
If the maximum output frequency setting is less than 10Hz, the output will be operated at 10Hz.
If the setting is more than 200KHz, the output will be operated at 200KHz.
Содержание ELC-PB
Страница 1: ......
Страница 5: ...For more information visit www eaton com MN05003003E iv...
Страница 29: ...ELC Programming Manual For more information visit www eaton com MN05003003E 1 24 MEMO...
Страница 502: ...3 Instruction Set MN05003003E For more information visit www eaton com 3 333...
Страница 601: ...ELC Programming Manual For more information visit www eaton com MN05003003E 3 432...
Страница 625: ...ELC Programming Manual For more information visit www eaton com MN05003003E 3 456...