3 . I n s t r u c t i o n S e t
M N 0 5 0 0 3 0 0 3 E F or m o r e i nf o r m a t i o n v i s i t : www. e a t o n. c o m
3-469
6. There is no limit to the number of times this instruction can be used in the program, but only one
can be executed at a time for each channel.
7. When the instruction is being executed, changes to the instruction parameters will be invalid.
Program Example:
1. When X0 = On, the output will be operated according to the frequency and number of pulses per
segment.
2. Format of the table:
S
2
= D300, number of
segments (D300 = K60)
S
1
= D0, frequency (
S
1
+ 0)
S
1
= D0, number of output
pulses (
S
1
+ 2)
K1 (1
st
segment)
D1, D0
D3, D2
K2 (2
nd
segment)
D5, D4
D7, D6
:
:
:
:
:
:
K60 (60
th
segment)
D237, D236
D239, D238
3. Monitor the segment number that is currently being executed in register D301.
X0
D0
DPTPO
D300
Y0
END
4. The pulse output curve:
Frequency (Hz)
t
t
t
t
1
2
....
60
(D1,D0)
(D3,D2)
(D239,D238)
(D5,D4)
(D237,D236)
....
....
(D7,D6)
Time (S)
Points to note:
1. ELC-PV
Flag
descriptions:
M1029: On when CH0 (Y0) pulse output is complete.
M1030: On when CH1 (Y2) pulse output is complete.
M1036: On when CH2 (Y4) pulse output is complete.
M1037: On when CH3 (Y6) pulse output is complete.
M1334: When On, CH0 (Y0) pulse output is in error.
Содержание ELC-PB
Страница 1: ......
Страница 5: ...For more information visit www eaton com MN05003003E iv...
Страница 29: ...ELC Programming Manual For more information visit www eaton com MN05003003E 1 24 MEMO...
Страница 502: ...3 Instruction Set MN05003003E For more information visit www eaton com 3 333...
Страница 601: ...ELC Programming Manual For more information visit www eaton com MN05003003E 3 432...
Страница 625: ...ELC Programming Manual For more information visit www eaton com MN05003003E 3 456...