DISPLAY AND PUSH-BUTTONS
The 4100L uses the same display as the 4100, but the main board electronics are the
same as the 4200. There is a single zero push-button on top of the scale, and optional
convert, print, tare or gross/net push-buttons are available. In addition to the external
ZERO button, the 4100L has all the push-buttons of the 4200, accessible by removing the
push-button access cover on the rear cover (see figure 7). These push-buttons can be
used to perform any of the functions supported by the 4200. They will probably be used
mostly for entering over and under values for checkweighing. Refer to figure 8 and the
appropriate sections in this manual for explanations of the functions of each of the
push-buttons.
Figure 7. 4100L Internal Push-buttons
SCALE OPERATION
All of the information in Section 4 of this manual is valid for the Model 4100L, although
typically not as many features are utilized. The 4100L typically has only an external ZERO
push-button and possibly an optional CONVERT or PRINT push-button. The internal
push-buttons can be used to perform any of the functions explained in Section 4, but the
most common is the entry of over and under value for checkweighing. In order to access
the internal push-buttons, the push-button access cover must be removed. See Section 4
for more information.
CHECKWEIGHING
Checkweighing is performed as outlined in Section 5 of this manual. Only zero
checkweighing can be performed, and only in the S42 tolerance mode (parameter 11)
since the 4100L does not have a bargraph display.
PARAMETER SETUP
The parameter setup mode operates the same as the 4200 - see Section 6. To enter the
setup mode and review or change the settings, the push-button access panel and the
calibration access cover must be removed to expose the internal push-buttons and the
setup switch. Follow the instructions in Section 6 to enter the setup mode and review or
change settings. Following Section 6 in the Model 4200 manual, these are the suggested
settings for the Model 4100L for most applications.
Section 9 Model 4100L
68
O V E R
U N D E R
T A R E
P R O D
N E T
G R O S S
P R I N T
C O N V
Z E R O