21. Scale I.D. (Id)
Option
Description
1
-30
Scale I.D. = selected number (1-30).
The Scale I.D. is used when a number of scales share the same serial communications
cable (network). When more than one scale is connected to a network, each scale must
have a unique address, or ID. This ID is used to prefix each command sent to the scale so
that only the proper scale will respond. Note that 00 cannot be used as an ID since this is a
broadcast ID that causes all scales on the network to respond.
22. Setpoint Entry Mode (S.P.t)
Option
Description
SEt
Setpoints entered via UP and DOWN arrow buttons.
P.t.t.
Setpoints entered using platform weight using the PROD button.
dlS
Setpoint entry disabled.
StA
Setpoint status mode.
The Setpoint Entry Mode parameter allows the user to select how the setpoint values are
entered in the 4200. Setpoint values can be entered digitally by using the UP or DOWN
arrows to enter the value or by placing the actual weight on the platform that corresponds to
the desired setpoint value.
If the setpoint entry mode is set for StA, the setpoint operation (see next page) should be
set for either hnA or LnA.
The 4 entry modes are explained fully in Section 4.
Section 6 Parameter Setup
42