Note, however, that when the operating mode of the 4200 (see below) is set for "Legal for
Trade", the "lb & oz" weight display mode is not a parameter option since it is not
recognized by NTEP or CWM as a legal for trade display. If the "lb & oz" option is selected
for SU and the operating mode is set for "Legal for Trade", the 4200 will start up in the "lb"
weight display mode. In addition, if a capacity of 500 lb or above (see below) is selected,
the "lb & oz" display is invalid and will not be a valid option since the graduation size is
greater than 2 oz.
Also, the unit can be set to display in grams instead of kilograms for the few capacities and
resolutions that have enough display capacity. In this case, the "kg" annunciator will
illuminate but the display will be in grams. When printing values, the 1.3 and 6 lb will always
print "g", and anything above 200 lb will always print "kg", all others will print the unit
selected either g or kg bases on the setting of the Start Up Unit.
Note: NTEP = National Type Evaluation Program
CWM = Canadian Weights and Measures
5a. Startup Gross/Net (SU)
Option
Description
grS
Startup in gross mode
nEt
Startup in net mode
This parameter is accessed by pressing the PRINT button when the Startup Units (S.U.)
parameter is selected. Each time PRINT is pressed, the option will toggle between grS
and nEt.
This option can be used in conjunction with the Push Button Enable parameter to start up in
the net mode when the push-buttons are disabled.
6. Scale Capacity (CAP)
OPTION
GRADS
CAPACITY AND RESOLUTION
1.3
3000
6000
10000
1.3 x .0005 lb / .600 x .0002 kg / 21 x .01 oz
1.3 x .0002 lb / .600 x .0001 kg / 21 x .005 oz
1.0 x .0001 lb / .454 x .00005 kg / 16 x .002 oz
3
3 x .001 lb / 1.3 x .0005 kg / 48 x .02 oz
3 x .0005 lb / 1.3 x .0002 kg / 48 x .01 oz
2 x .0002 lb / .9 x .0001 kg / 32 x .005 oz
6
6 x .002 lb / 2.7 x .001 kg / 96 x .05 oz
6 x .001 lb / 2.7 x .0005 kg / 96 x .02 oz
5 x .0005 lb / 2.3 x .0002 kg / 80 x .01 oz
Section 6 Parameter Setup
31