11. Tolerance [Over/Under] Entry Mode (toL)
Option
Description
S42
4200 Std. emulate (SEt)
P42
4200 Std. emulate (P.t.t.)
d42
4200 emulate, disable entry (Dis)
S d
Value per bar entered via UP and DOWN arrows.
P d
Value per bar entered by a press of OVER or UNDER button.
d d
Value per bar, disable entry.
S S
Scaled value entered via UP and DOWN arrows.
P S
Scaled value entered by single press of OVER or UNDER button.
d S
Scaled value, disable entry.
SdA
Modified value per bar, Over and Under entered via arrows, value per bar calculated from
over and under values.
PdA
Modified value per bar, Over and Under entered by press of OVER or UNDER buttons,
value per bar calculated from Over and Under values.
ddA
Modified value per bar, disable entry.
NOTE: When 4200 emulation is selected, the Over and Under areas on the bargraph
indicator will all be turned on when the scale senses either Over or Under weights.
The Tolerance Entry Mode parameter allows the user to select how the Over and Under
tolerance values on the 4200 are entered, and how the bargraph display operates. The
first letter of the option denotes the entry mode. The three entry modes (as explained in
Section 5) are SET, PTT, and DIS. The remaining letters or numbers denote the bargraph
operation mode. These modes (also explained in Section 5) are 4200 Emulate, Value per
Bar, Scaled, and Modified Value per Bar.
The OVER and UNDER buttons can be disabled using the DIS mode if they are not to be
used, or if it is desired to preset tolerances and secure them from tampering by the scale
operator.
NOTE : It is not recommended that the scaled bargraph settings (SS,PS,dS) be used for
"Legal for Trade" applications.