9. Push-button Enable (P.b.)
Option
Description
non
Neither "UNITS" nor "PRINT" enabled.
C
Only "UNITS" enabled.
P
Only "PRINT" enabled.
C P
Both "UNITS" and "PRINT" enabled.
Z
All push-buttons disabled except ZERO.
ZPr
All push-buttons disabled except ZERO, PROD, and the UP and DOWN arrows.
This parameter allows the user to enable or disable the UNITS and PRINT buttons
separately. Additionally, all the push-buttons on the panel, except the ZERO button, can be
disabled for cases where operator tampering is to be discouraged by selecting the "Z"
option. The "ZPr" option disables all buttons except ZERO, PROD, UP, and DOWN. This
allows the operator to choose different products for tare and checkweighing operations
without the ability to change any of the values.
9a. Beeper Enable (BEEPON/BEEPOFF)
The Beeper Enable provides a method for enabling or disabling the keyboard push-button
beeper. To enable/disable the beeper, press the PRINT button while the parameter menu
is in Push Button Select (P.b.). The parameter will alternate between BEEPON and
BEEPOFF every time PRINT is pressed.
10. Displayed Resolution (CtS)
Option
Description
3
1:3000 displayed resolution
6
1:6000 displayed resolution
The 4200 is provided with the ability to increase its displayed resolution from a nominal 1
part in 3000 to 1 part in 6000. This ability is provided for users who require finer resolution
weighing for more precise checkweighing. It should be noted however, that the 4200 is
only intended to be certified as "Legal for Trade" up to the 1 part in 3000 displayed
resolution. Make sure that your application does not require this certification before
selecting the higher resolution.
10a. Extended Resolution (CtS)
1:10000 displayed resolution is also available. To enable this option press the PRINT
button when the CtS parameter is selected. This brings up the "10" option for high
resolution.
Section 6 Parameter Setup
35