The Print Format parameter allows the 4200 to print a variety of formats for different
applications and printer requirements. Select the format that best fits your data and printer
requirements.
16. Checkweigh Operation (C.O.)
Option
Description
n A
Net only, all time.
n S
Net only, only stable weights.
n t
Net only, only weights above 1% of scale capacity.
n b
Net only, only stable weights above 1% of scale capacity.
g A
Gross only, all time.
g S
Gross only, only stable weights.
g t
Gross only, only weights above 1% of scale capacity.
g b
Gross only, only stable weights above 1% of scale capacity.
b A
Gross & Net, all time.
b S
Gross & Net, only stable weights.
b t
Gross & Net, only weights above 1% of scale capacity.
b b
Gross & Net, only stable weights above 1% of scale capacity.
OFF
Disable tolerance indicators.
The Checkweigh Operation parameter specifies the conditions under which the bargraph
indicators are active. If the conditions are not met, the indicators will be off, e.g. if set for
bS, and the scale is in motion, the indicators will be off.
This parameter also controls the Over, Under, and Accept outputs of the scale. This is
particularly useful when external beepers are used to signal the checkweigh status. In this
case, the threshold (1%) parameter is usually used so that the beepers do not activate until
a weight is placed on the scale.
Section 6 Parameter Setup
39