When the correct setpoint is displayed, press the PROD button once more and the display
will show the current value entered for the setpoint selected. If the value is just being
recalled, pressing the PROD button again will return the scale to normal weighing with no
change to the setpoint value. If the value needs to be changed, refer to the explanations
below for information on the various entry modes.
Note - if no buttons are pressed for about 6 seconds, the display will automatically revert
back to the normal weighing mode without changing any values.
SET MODE
This is the digital entry mode. Setpoint values are entered using the UP or DOWN
arrows to modify the value shown on the display. To change a value, select the
desired setpoint and recall its value as outlined above. Next, press the UP or
DOWN arrows to increase or decrease the displayed value. Once the proper value
has been selected, press the PROD button to enter the value as the new setpoint
value. The display will show the message "ENT PR". If the display shows anything
else ("ER XX"), the value will not be entered and the old value is retained. The
scale will then return to normal weighing automatically.
PTT MODE
This is the platform weight entry mode. Setpoint values are entered using the actual
weight on the platform. To enter a new value, select the desired setpoint and recall
its value as explained above. Next, place the weight that is to be the new setpoint
value on the platform and press and hold the PROD button for about 2 seconds.
The scale will verify that the value has been entered with the message "ENT PR." If
any other message is displayed ("ER XX"), the weight on
the platform was not entered as the new setpoint value and the old value is retained
and displayed. To exit, press the PROD button again and the scale will return to
normal weighing.
DIS MODE
This is the "disable entry" mode. If this mode is chosen, the setpoint values can only
be recalled, not changed. This is sometimes necessary to prevent tampering or
accidental loss of values. Normally the mode is set to SET or PTT to enter the
values, and then changed to DIS to prevent changing them. The values can be
recalled by using the procedure above to select and recall setpoints.
Section 4 Scale Operation
17