Modified Value per Bar (SdA, PdA, ddA)
This mode can be used for zero or net checkweighing and is similar to the Value per Bar
mode. The difference is that the values per bar are calculated instead of specified. The
Over value determines the over point, the Under value determines the under point, and the
value per bar is found by dividing the difference between the Over and Under values by 10.
Note: Value per Bar must be greater than the scale division.
In the following examples, the Over value is set to 0.5 lb, and the Under Value is set to -0.5
lb (value per bar = 0.1 lb).
U N D E R
ACCEPT
O V E R
Example 1 - weight on scale = -0.7 lb
U N D E R
ACCEPT
O V E R
Example 2 - weight on scale = 0.3 lb
U N D E R
ACCEPT
O V E R
Example 3 - weight on scale = 1.1 lb
Section 5 Checkweighing
25