SiEBE18-526
Outdoor Unit
Removal Procedure
349
1.4
Removal of Thermistor Assembly
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Removing the thermistors
1
Remove the under cool
thermistor.
2
Remove the suction
pipe thermistor.
3
Remove the discharge
pipe thermistor.
(Q0494)
Suction pipe
thermistor
Under cool
thermistor
Discharge pipe
thermistor