VII. DUST FROM THE UNITS
• Dust may blow out from the unit after starting
operation from long resting time.
Dust absorbed by the unit blows out.
VIII. THE UNITS GIVE OFF ODORS
The
unit absorbs the smell of rooms, furniture,
cigarettes, etc., and then emits them.
IX. THE LIQUID CRYSTAL OF THE REMOTE
CONTROL SHOW “
”
• It happens immediately after the main power
supply switch is turned on.
This shows that the remote control is in normal
condition.
This continues temporary.
10. TROUBLE SHOOTING
I. If one of the following malfunctions occurs,
take the measures shown below and contact
your Daikin dealer.
The system must be repaired by a qualified
service person.
WARNING
When the air conditioner is in abnormal
conditions (smell of something burning, etc),
unplug the power cord from the outlet, and
contact your dealer
Continued operation under such circumstances
may result in a failure, electric shock, and fire.
•
If a safety device such as a fuse, a breaker, or
an earth leakage breaker frequently actuates, or
ON/OFF switch does not properly work.
Measure:
Turn off the main power switch
•
If water leaks from unit.
Measure:
Stop the operation.
•
If the display “
” (INSPECTION), “UNIT No.”,
and the OPERATION lamp flash and the
“MALFUNCTION CODE” appears.
INSPECTION
display
OPERATION lamp
INDOOR UNIT
No. in which a
malfunction occurs.
MALFUNCTION CODE
Measure:
Notify your Daikin dealer and inform
him/her of the display.
II. If the system does not properly operate
except for the above mentioned case, and
none of the above mentioned malfunctions is
evident, investigate the system according to
the following procedures.
1. If the system does not operate at all.
•
Check if there is a power failure.
Wait until power is restored. If power failure
occurs during operation, the system automati-
cally restarts immediately after the power
supply recovers.
•
Check if the fuse has blown or breaker has
worked.
Change the fuse or set the breaker.
2. If the system stops operating after operating
the system.
•
Check if the air inlet or outlet of outdoor or
indoor unit is blocked by obstacles.
Remove the obstacle and make it well-
ventilated.
•
Check if the air filter is clogged.
Ask a qualified service person to clean the air
filters (Refer to MAINTENANCE).
3. The system operates but it does not suffi-
ciently cool or heat.
•
If the air inlet or outlet of the indoor or the
outdoor unit is blocked with obstacles.
Remove the obstacle and make it well-
ventilated.
•
If the air filter is clogged.
Ask a qualified service person to clean the air
filters (Refer to MAINTENANCE).
•
If the set temperature is not proper (Refer to
ADJUSTMENT).
•
If the FAN SPEED button is set to LOW
SPEED (Refer to ADJUSTMENT).
•
If the air flow angle is not proper (Refer to AIR
FLOW DIRECTION ADJUST).
•
If the doors or the windows are open.
Shut doors or windows to prevent wind from
coming in.
•
If direct sunlight enters the room (when
cooling).
Use curtains or blinds.
•
When there are too many inhabitants in the
room (when cooling).
Cooling effect decreases if heat gain of the
room is too large.
•
If the heat source of the room is excessive
(when cooling).
Cooling effect decreases if heat gain of the
room is too large.
3PN05140-1T
Содержание Super Multi Plus D-Series
Страница 1: ...SiEBE18 526 D Series Service Manual Applied Models zSuper Multi Plus Heat Pump...
Страница 12: ...SiEBE18 526 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Страница 63: ...Refrigerant Flow for Each Operation Mode SiEBE18 526 52 Refrigerant Circuit...
Страница 167: ...Instruction SiEBE18 526 156 System Configuration FDXS25 35C CDXS50 60C 3 6 8 9 10 7 1 4 5 2 Names of parts Indoor Unit...
Страница 249: ...Instruction SiEBE18 526 238 System Configuration...
Страница 395: ...2 5 DS1 3 DS1 4 BP Unit ON OFF Connect BP unit Not connect BP unit Do not change the factory setting Not Used...