SiEBE18-526
Instruction
System Configuration
229
If the temperature or the humidity is beyond the following
conditions, safety devices may work and the air conditioner
may notoperate, or sometimes, water may drop from the
indoor unit.
COOLING
3. OPERATION RANGE
Be sure the air conditioner is electrically grounded.
Do not connect the grounding conductor to a gas pipe,
water pipe, lightning arrester, and the grounding
conductor for a telephone.
Imperfect grounding work may result in an electric shock.
Execute complete drain piping for perfect
drainage.
Incomplete piping may result in a water leakage.
The appliance is not intended for use by
young children or infirm persons without
supervision.
Young children should be supervised to ensure
that they do not play with the appliance.
OUTDOOR UNIT
INDOOR
OUTDOOR
TEMPERA-
TURE
HUMID-
ITY
TEMPERA-
TURE
R35 · 45 · 60
RY35 · 45 · 60
R71 · 100 · 125
RP71 · 100 · 125
REP71 · 100 · 125
RY71 · 100 · 125
RYP71 · 100 · 125
RYEP71 · 100 · 125
RZP71 · 100 · 125
RQ71 · 100 · 125
RR71 · 100 · 125
RZQ71 · 100 · 125 ·
140
RS50 · 60
RKS35 · 50 · 60
RXS35 · 50 · 60
3MKS50
4MKS58 · 75 · 90
3MXS52 · 2MXS52
4MXS68 · 80
RMKS112 · 140 · 160
RMXS112 · 140 · 160
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
WB
WB
WB
WB
WB
WB
WB
WB
WB
WB
WB
18 to 33
18 to 33
12 to 24
12 to 24
21 to 35
21 to 35
21 to 32
21 to 32
21 to 32
14 to 25
14 to 25
14 to 23
14 to 23
14 to 23
12 to 25
12 to 28
12 to 28
12 to 28
18 to 35
18 to 37
18 to 37
18 to 37
80% or
below
80% or
below
80% or
below
80% or
below
80% or
below
80% or
below
80% or
below
80% or
below
80% or
below
80% or
below
80% or
below
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB – 5 to 46
– 10 to 46
– 10 to 46
– 15 to 50
– 5 to 50
– 15 to 46
– 15 to 46
– 15 to 46
– 5 to 46
– 5 to 46
– 5 to 46
OUTDOOR UNIT
INDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
HEATING
15 to 27
15 to 27
15 to 27
10 to 30
10 to 30
10 to 30
10 to 27
10 to 27
DB
DB
DB
DB
DB
DB
DB
DB
RY35 · 45 · 60
RY71 · 100 · 125
RYP71 · 100 · 125
RYEP71 · 100 · 125
RZP71 · 100 · 125
RQ71 · 100 · 125
RMXS112 · 140 · 160
3MXS52 · 2MXS52
4MXS68 · 80
RXS35 · 50 · 60
RZQ71 · 100 · 125 ·
140
DB
WB
DB
WB
DB
WB
DB
WB
DB
WB
DB
WB
DB
WB
DB
WB
– 9 to 21
– 10 to 15.5
– 10 to 15.5
– 15 to 15.5
– 15 to 15.5
– 15 to 15.5
– 15 to 18
– 20 to 15.5
– 9 to 21
– 14 to 21
– 14 to 21
– 14 to 21
– 14 to 24
– 9 to 21
– 10 to 15
– 19.5 to 21
D B: Dry bulb temperature (°C)
WB: Wet bulb temperature (°C)
The setting temperature range of the remote
control is 16°C to 32°C.
4. INSTALLATION SITE
Regarding places for installation
• Is the air conditioner installed at a well-
ventIlated place where there are no obstacles
around?
• Do not use the air conditioner in the following
places.
a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach
area
c. Where
sulfured gas exists such as a hot-
spring resort
d. Where
there
are considerable voltage fluctua-
tions such as a factory or plant
e. Vehicles and vessels
f. Where there is much spray of oil and vapor
such as a cookery, etc.
g. Where
there
are machines generating electro-
magnetic waves
h. Filled
with
acid and/or alkaline steam or vapor
• Is a snow protection measure taken?
For
details, consult your dealer.
Regarding wiring
• All wiring must be performed by an autho-
rized electrician.
To do wiring, ask your dealer. Never do it by yourself.
Содержание Super Multi Plus D-Series
Страница 1: ...SiEBE18 526 D Series Service Manual Applied Models zSuper Multi Plus Heat Pump...
Страница 12: ...SiEBE18 526 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Страница 63: ...Refrigerant Flow for Each Operation Mode SiEBE18 526 52 Refrigerant Circuit...
Страница 167: ...Instruction SiEBE18 526 156 System Configuration FDXS25 35C CDXS50 60C 3 6 8 9 10 7 1 4 5 2 Names of parts Indoor Unit...
Страница 249: ...Instruction SiEBE18 526 238 System Configuration...
Страница 395: ...2 5 DS1 3 DS1 4 BP Unit ON OFF Connect BP unit Not connect BP unit Do not change the factory setting Not Used...