Field Setting
SiEBE18-526
116
Test Operation
No.
Setting item display
Setting condition display
Setting item
MODE
H1P
TEST
H2P
C/H selection
Low
noise
H6P
Demand
H7P
IND
H3P
Master
H4P
Slave
H5P
∗
Factory set
5
Indoor forced fan H
8
7
7
7
8
7
8
Normal operation
8777778
∗
Indoor forced fan H
8777787
6
Indoor forced
operation
8
7
7
7
8
8
7
Normal operation
8777778
∗
Indoor forced operation
8777787
8
Te setting
8
7
7
8
7
7
7
High(H)
8777877
Normal (M)
8777787
∗
Low(L)
8777778
9
Tc setting
8
7
7
8
7
7
8
High(H)
8777877
Normal(M)
8777787
∗
Low(L)
8777778
10 Defrost setting
8
7
7
8
7
8
7
Quick defrost
8777877
Normal
8777787
∗
Slow defrost
8777778
21
Refrigerant recovery
mode setting
8
7
8
7
8
7
8
Refrigerant recovery: OFF
8777778
∗
Refrigerant recovery: ON
8777787
22
Night quiet mode
setting
8
7
8
7
8
8
7
OFF
8777777
∗
Level 1
8777778
Level 2
8777787
Level 3
8777788
26
Night quiet mode
control start setting
8
7
8
8
7
8
7
About 20:00
8777778
About 22:00
8777787
∗
About 24:00
8777877
27
Night quiet mode
control end setting
8
7
8
8
7
8
8
About 6:00
8777778
About 7:00
8777787
About 8:00
8777877
∗
29
Capacity
precedence setting
8
7
8
8
8
7
8
OFF
8777778
∗
ON
8777787
30 Demand setting 1
8
7
8
8
8
8
7
60 % demand
8777778
70 % demand
8777787
∗
80 % demand
8777877
31 Demand setting 2
8
7
8
8
8
8
8
30 % demand
8777778
40 % demand
8777787
∗
50 % demand
8777877
32
Continuous demand
setting
8
8
7
7
7
7
7
OFF
8777778
∗
ON
8777787
Содержание Super Multi Plus D-Series
Страница 1: ...SiEBE18 526 D Series Service Manual Applied Models zSuper Multi Plus Heat Pump...
Страница 12: ...SiEBE18 526 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Страница 63: ...Refrigerant Flow for Each Operation Mode SiEBE18 526 52 Refrigerant Circuit...
Страница 167: ...Instruction SiEBE18 526 156 System Configuration FDXS25 35C CDXS50 60C 3 6 8 9 10 7 1 4 5 2 Names of parts Indoor Unit...
Страница 249: ...Instruction SiEBE18 526 238 System Configuration...
Страница 395: ...2 5 DS1 3 DS1 4 BP Unit ON OFF Connect BP unit Not connect BP unit Do not change the factory setting Not Used...