SiEBE18-526
Instruction
System Configuration
231
1
2
FAN SPEED CONTROL BUTTON
Press this button to select the fan speed,
HIGH or LOW, of your choice.
OPERATION MODE SELECTOR BUTTON
Press this button to select OPERATION
MODE.
AIR FLOW DIRECTION ADJUST BUTTON
Refer to “AIR FLOW DIRECTION ADJUST ”.
20
21
22
NOTE
•
For the sake of explanation, all indications are
shown on the display in Figure 1 contrary to
actual running situations.
6. OPERATION PROCEDURE
Refer to figure 1 on page [1]
•
Operating procedure varies with heat pump type
and cooling only type. Contact your Daikin dealer
to confirm your system type.
•
To protect the unit, turn on the main power switch
6 hours before operation.
•
If the main power supply is turned off during
operation, operation will restart automatically
after the power turns back on again.
COOLING, HEATING, AUTOMATIC, FAN,
AND PROGRAM DRY OPERATION
Operate in the following order.
OPERATION MODE SELEC-
TOR
Press OPERATION MODE SELECTOR
button several times and select the OPERA-
TION MODE of your choice as follows.
COOLING OPERATION ......................“
”
HEATING OPERATION .......................“
”
AUTOMATIC OPERATION ..................“
”
•
In this operation mode, COOL/HEAT change-
over is automatically conducted.
FAN OPERATION ................................“
”
DRY OPERATION ...............................“
”
•
The function of this program is to decrease the
humidity in your room with the minimum
temperature decrease.
•
Micro computer automatically determines
TEMPERATURE and FAN SPEED.
•
This system does not go into operation if the
room temperature is below 16°C.
Refer to figure 3 on page [1]
•
For cooling only type, “COOLING” , “FAN” and
“DRY” operation are able to select.
ON/OFF
Press ON/OFF BUTTON
OPERATION lamp lights up or goes off and the
system starts or stops OPERATION.
[EXPLANATION OF HEATING OPERATION]
DEFROST OPERATION
•
As the frost on the coil of an outdoor unit increase,
heating effect decreases and the system goes into
DEFROST OPERATION.
•
The indoor unit fan stops and the remote control
display shows “
”.
•
After 6 to 8 minutes (maximum 10 minutes) of
DEFROST OPERATION, the system returns to
HEATING OPERATION.
Regarding outside air temperature and
heating capacity
•
The heating capacity of the air conditioner
declines as the outside air temperature falls. In
such a case, use the air conditioner in combina-
tion with other heating systems.
•
A warm air circulating system is employed, and
therefore it takes some time until the entire room
is warmed up after the start of operation.
•
An indoor fan runs to discharge a gentle wind
automatically until the temperature inside the air
conditioner reaches a certain level. At this time,
the remote control displays “
”. Leave it as it
stands and wait for a while.
•
When the warm air stays under the ceiling and
your feet are cold, we recommend that you use a
circulator (a fan to circulate the air inside the
room). For details, consult your dealer.
Содержание Super Multi Plus D-Series
Страница 1: ...SiEBE18 526 D Series Service Manual Applied Models zSuper Multi Plus Heat Pump...
Страница 12: ...SiEBE18 526 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Страница 63: ...Refrigerant Flow for Each Operation Mode SiEBE18 526 52 Refrigerant Circuit...
Страница 167: ...Instruction SiEBE18 526 156 System Configuration FDXS25 35C CDXS50 60C 3 6 8 9 10 7 1 4 5 2 Names of parts Indoor Unit...
Страница 249: ...Instruction SiEBE18 526 238 System Configuration...
Страница 395: ...2 5 DS1 3 DS1 4 BP Unit ON OFF Connect BP unit Not connect BP unit Do not change the factory setting Not Used...