Instruction
SiEBE18-526
222
System Configuration
1
2
3
Press the AIR FLOW DIRECTION ADJUST
button to select the air direction as following.
The AIR FLOW FLAP display
swings as shown left and the
air flow direction continuously
varies. (Automatic swing
setting)
swing
Press AIR FLOW DIRECTION
ADJUST button to select the air
direction of your choice.
The AIR FLOW FLAP display
stops swinging and the air
flow direction is fixed (Fixed
air flow direction setting).
MOVEMENT OF THE AIR FLOW FLAP
For the following conditions, micro computer
controls the air flow direction so it may be different
from the display.
Operation
mode
Heating
Operation
condition
• When starting operation
• When room temperature is higher
than the set temperature
• At defrost operation
(Air
is blown horizontally to prevent
the cool air from being blown
directly onto anyone in the room.)
Operation mode includes automatic operation.
PROGRAM TIMER OPERATION
TIMER MODE START/STOP
Press the TIMER MODE START/STOP
button several times and select the
mode on the display.
The display flashes.
For setting the timer stop..... “
”
For setting the timer start .... “
”
Operate in the following order.
• The timer is operated in the following two ways.
• Programming the stop time ( ) .... The
system stopsoperating after the set time has
elapsed.
• Programming the start time ( ) .... The
system startsoperating after the set time has
elapsed.
• The timer can be programmed a maximum of 72
hours.
• The start and the stop time can be simulta-
neously programmed.
PROGRAMMING TIME
TIMER ON/OFF
Press the PROGRAMMING TIME button and
set the time for stopping or starting the
system.
When this button is pressed, the time
advances by 1 hour.
When this button is pressed, the time
goes backward by 1 hour.
Press the TIMER ON/OFF button.
The timer setting procedure ends.
The display “ or
” changes from
flashing light to a constant light.
Refer to figure 4 on page
[1]
NOTE
• When setting the timer Off and On at the same
time, repeat the above procedure from
1
to
3
once again.
When the timer is programmed to stop the system
after 3 hours and start the system after 4 hours, the
system will stop after 3 hours and then 1 hour later
the system will start.
• After the timer is programmed, the display shows
the remaining time.
• Press the TIMER ON/OFF button once again to
cancel programming. The display vanishes.
7. OPTIMUM OPERATION
Observe the following precautions to ensure the
system operates.
• Adjust the room temperature properly for a
comfortable environment. Avoid excessive heating
or cooling.
• Prevent direct sunlight from entering a room during
cooling operation by using curtains or blinds.
• Ventilate the room regularly.Using the unit for long
periods of time requires attentive ventilation of the
room.
• Do not place items that might be damaged by
water under the indoor unit.
Water may condensate and drip if the humidity
reaches 80% or if the drain exit gets clogged.
• Keep doors and windows closed. If the doors and
windows remain open, room air will flow out and
cause to decrease the effect of cooling and
heating.
Содержание Super Multi Plus D-Series
Страница 1: ...SiEBE18 526 D Series Service Manual Applied Models zSuper Multi Plus Heat Pump...
Страница 12: ...SiEBE18 526 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Страница 63: ...Refrigerant Flow for Each Operation Mode SiEBE18 526 52 Refrigerant Circuit...
Страница 167: ...Instruction SiEBE18 526 156 System Configuration FDXS25 35C CDXS50 60C 3 6 8 9 10 7 1 4 5 2 Names of parts Indoor Unit...
Страница 249: ...Instruction SiEBE18 526 238 System Configuration...
Страница 395: ...2 5 DS1 3 DS1 4 BP Unit ON OFF Connect BP unit Not connect BP unit Do not change the factory setting Not Used...