Service Check Function
Troubleshooting
247
5. Press the TEMP button.
Press TEMP
s
or TEMP
t
and change the digit until you hear the sound of “beep”.
6. Diagnose by the sound.
H
“ pi ” : The both numbers of tens and units do not accord with the error code.
H
“ pi pi ” : The number of tens accords with the error code.
H
“ beep ” : The both numbers of tens and units accord with the error code.
7. Determine the error code.
The digits indicated when you hear the “beep” sound are error code.
8. Exit from the diagnosis mode.
Press the MODE button.
Error Code List in
Relation to RA
Indoor Units
- : Not used for troubleshooting
(R4277)
(R4278)
Indication on
the remote
controller
Description of the Fault
Details of fault
(Refer to the
indicated
page.)
00
Indoor unit in normal condition (Conduct a diagnosis of the outdoor
unit.)
—
A1
Indoor unit PCB abnormality
257
A5
Freeze-up protection control or high pressure control (heat pump
model only)
258
A6
Fan motor or related
abnormality
AC motor (Wall : 20~35 C series, Duct, Floor /
Ceiling)
260
DC motor (Wall : 20~35 D series and 50~71 B
series, Floor)
261
C4
Heat exchanger thermistor or related abnormality
263
C7
Shutter drive motor / shutter limit switch abnormality
264
C9
Room temperature thermistor abnormality
263
Содержание Super Multi Plus D-Series
Страница 1: ...SiEBE18 526 D Series Service Manual Applied Models zSuper Multi Plus Heat Pump...
Страница 12: ...SiEBE18 526 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Страница 63: ...Refrigerant Flow for Each Operation Mode SiEBE18 526 52 Refrigerant Circuit...
Страница 167: ...Instruction SiEBE18 526 156 System Configuration FDXS25 35C CDXS50 60C 3 6 8 9 10 7 1 4 5 2 Names of parts Indoor Unit...
Страница 249: ...Instruction SiEBE18 526 238 System Configuration...
Страница 395: ...2 5 DS1 3 DS1 4 BP Unit ON OFF Connect BP unit Not connect BP unit Do not change the factory setting Not Used...