3
|
Components
Service manual
283
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
3
Cut all tie straps that fix the wiring harness, and remove the wiring harness
from the unit.
4
To install the water pump appropriate wiring harness, see
279].
To install the water pump wiring harness
1
Connect the wiring harness to the appropriate connector:
▪
X16A on hydro PCB for power supply wiring harness
▪
X25A on hydro PCB for PWM signal wiring harness
2
Route the wiring harness towards the water pump and connect the wiring
harness to the appropriate connector (power supply and/or PWM signal) of
the water pump.
3
Fix the wiring harness using new tie straps.
Is the problem solved?
Action
Yes
No further actions required.
No
Return to the troubleshooting of the
specific error and continue with the
next procedure.