3
|
Components
Service manual
109
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
a
c
d
e
f
g
b
a
Backup heater thermal protector sensor
b
Air purge valve
c
Screw (pipe clamp)
d
Pipe clamp
e
Clip
f
Upper backup heater coupling
g
Backup heater
5
Remove the clip from the upper backup heater coupling.
6
Remove the pipe from the pipe clamp to improve manoeuvrability of the
backup heater.
7
Separate the upper backup heater coupling.
INFORMATION
Make sure that the O-ring stays in place.
8
Remove the clip from the lower backup heater coupling.
a
b
c
a
Clip
b
Lower backup heater coupling
c
Backup heater
9
Separate the lower backup heater coupling.