3
|
Components
Service manual
198
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
2
Measure the voltage on the output connector X98A and between the pins 1‑2
of output connector X803A.
Result:
The measured voltage MUST be 230 V AC.
b
a
c
d
a
LB
b
NB
c
Connector X98A
d
Connector X803A
Is the output voltage on the noise filter
PCB correct?
Action
Yes
PCB and continue with the next
procedure.
No
Replace the noise filter PCB, see
To check if the correct spare part is installed
Prerequisite:
First perform all earlier checks of the noise filter PCB, see
1
Visit your local spare parts webbank.
2
Enter the model name of your unit and check if the installed spare part
number corresponds with the spare part number indicated in the webbank.
Is the correct spare part for the noise
filter PCB installed?
Action
Yes
PCB and continue with the next
procedure.
No
Replace the noise filter PCB, see