3
|
Components
Service manual
179
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
4
Loosen the screws to disconnect the LC, NC, U, V and W wires.
5
Remove all main PCB fixation screws.
6
Pull the refrigerant pipe forward and move the main PCB out.
7
Remove the bottom screw on the back of the main PCB to disconnect the
ground wire.
8
To install the main PCB
1
Use a piece of cloth to remove the old thermal interface grease and clean the
refrigerant pipe.
2
Install the ground wire at the bottom back side of the main PCB. Install and
tighten the screw.
3
Apply grease to the refrigerant pipe contact surface of the heat sink (on the
main PCB). Distribute the grease as evenly as possible.
CAUTION
ALWAYS apply new grease on the PCB heat sink. NOT doing so may cause the PCB to
fail due to insufficient cooling.
4
Carefully pull the refrigerant pipe forward and install the main PCB on its
mounting plate in the correct location. Install and tighten the fixation screws.
INFORMATION
Make sure that the refrigerant pipe is correctly installed on the main PCB heat sink.
Do NOT touch the part of the refrigerant pipe that is mounted in the heat sink.
5
Install the heat sink cover. Close and slide it downwards to fix the 2 hooks.
6
Install and tighten the 3 screws so that the heat sink cover presses the
refrigerant pipe.
d
a
a
a
b
c
c
c
e
d
d
d
d
d
d
d
d
d
d
d
d
d
d
d
a
Heat sink cover screw
b
Heat sink cover
Содержание ALTHERMA
Страница 357: ...11 11 ...
Страница 358: ......
Страница 359: ......
Страница 360: ...ESIE20 06A 2021 03 Copyright 2021 Daikin Verantwortung für Energie und Umwelt ...