3
|
Components
Service manual
170
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
a
b
a
Low pressure switch
b
Low pressure switch pipe
CAUTION
Overheating the pressure switch will damage or destroy it.
5
After soldering is done, stop the nitrogen supply after the component has
cooled‑down.
6
Install the brackets and clip on the low pressure switch and pipe.
7
Install and tighten the screws.
a
a
b
c
b
a
Screw
b
Bracket
c
Clip
8
Route the low pressure switch harness towards the appropriate PCB.
9
Fix the harness using new tie straps.
10
Connect the low pressure switch connector to the appropriate PCB.
11
12
Add
refrigerant
to
the
refrigerant
circuit,
see
Is the problem solved?
Action
Yes
No further actions required.