3
|
Components
Service manual
281
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
Is the problem solved?
Action
Yes
No further actions required.
No
Return to
276] of the water pump
and continue with the next procedure.
To remove the water pump housing
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
Drain water from the water circuit, see
2
Disconnect the connectors from the water pump motor.
b
c
a
a
a
Connector
b
Nut
c
Water pump housing
3
Unscrew the upper and lower nuts that fix the water pump housing to the
water circuit pipes.
CAUTION
Use a counterforce when unscrewing or tightening the nuts to make sure NOT to
damage the piping.
4
Remove the water pump housing.
5
To install the water pump housing, see
To install the water pump housing
1
Install the water pump housing in the correct location.