TGL/DGL Installation Instructions
General
●
These instructions are intended as general guidelines. The air conditioner must be installed by trained and authorized personnel.
●
Use the following size copper tubing for connecting the outdoor and indoor units:
Models TGL/DGL 9, 11 - 3/8" and 1/4". Models TGL/DGL 15, 20, 25 - 1/4" and 1/2". Models TGL 30 - 3/8" and 5/8".
●
Installation must be performed in accordance with the manufacturer’s specifications, using only approved tubing, original electrical
cables and accessories.
Standard Accessories
Electrical Requirements
●
The air conditioner must be directly connected to an
appropriate power source.
●
Use 16A fuses for all Models TGL/DGL air conditioners.
●
Use a single-length power cable, without extensions.
●
When installing a Dual System air-conditioner of DGL
series (a single outdoor unit and two separate indoor units)
both indoor units must be connected to the mains power supply in order for the system to function properly.
Indoor and Outdoor Unit Location
The indoor and outdoor units should be installed as
close to each other as possible. Do not exceed the tubing
lengths and height differences which appear in the accompanying
table above:
Outdoor Unit
●
Make sure to leave sufficient space around the unit. See Figure 1 for
minimum required distances between the unit and nearby walls.
●
Install the unit in a location with convenient access for service and
maintenance purposes.
●
Position the unit to minimize motor noise which reaches the customer
and neighbors.
●
In heating mode, water can form in the condenser. A drainage hose may
be attached to the unit. Use the adapter shown Figure 1.
●
For opening service door in models TGL 9-20, keep a minimum distance of
0.27m (10" 62') between the unit and the support's end.
●
Make sure of installing the unit legs to the support.
Indoor Unit
●
Make sure to leave sufficient space around the unit. See Figure 2 for minimum
required distances between the unit and the ceiling, floor and surrounding walls.
●
Locate the unit to ensure free air flow around it.
●
A 120 cm. power cable is supplied with the unit. We recommend placing the power
outlet near the unit, on its right side.
●
Avoid installing the unit near a
source of heat, such as direct
sunlight, steam or a flame.
●
Install the unit in a location
with convenient access to
refrigerant line connections
for service and maintenance
purposes.
0.15m (6") min.
0.2m
(8")
min.
1.8
−2
.5m
(6'-8'3") min.
b
c
a
0.2m
(8")
min.
Fig. 1
Model
Maximum tubing
Maximum height
length in meters (ft)
difference between unit
in meters (ft)
TGL-9, 11, 15, 20, 25, 30
15 (49')
10 (33')
DGL-9, 11, 15, 20
15 (49')
10 (33')
DGL-11/15
15 (49')
10 (33')
Outdoor
Model
Dimensions
TGL 9-20
TGL 25-30
mm (")
DGL ALL
Plastic Model
a
320
(32.3")
265
(45.3")
b
641
(12.6")
540
(13.8")
c
1100
(6.7")
730
(7.9")
Fig. 2
Indoor
Model
Dimensions
TGL 9-20
TGL 25-30
mm (")
a
185
(32.3")
185
(45.3")
b
260
(12.6")
295
(13.8")
c
815
(6.7")
1080
(7.9")
Drain hose adapter
for
≠
≠
≠
≠
≠
DGL/TGL 9-20
WIRELESS DIGITAL REMOTE CONTROLLER
WIRELESS DIGITAL REMOTE CONTROLLER
WIRELESS DIGITAL REMOTE CONTROLLER
WIRELESS DIGITAL REMOTE CONTROLLER
S TA R T
S T O P
1 2 3 S L E E P
D A I LY
M O D E
FA N
S W E E P
Drain hose adapter
for
≠
≠
≠
≠
≠
DGL/TGL 25-30
Remote Controller
and Batteries
Remote Controller Rack
Insulation for Fittings
User's Manual
Wall Plugs
Long Screws
Mounting Bracket
Outdoor sensor
connecting cable
Absorption cushions
for DGL and TGL 25-30
Electrical terminal block
6/7 stations according
to the model
0.6m(2')
min.
0.15m(6")
min.
a
c
0.6m(2')
min.
0.15m(6")
min.
0.6m
(2')
min
.
b
0.6m(2')
0.15m(6")
min.
min.
min.
min.
min.
b
a
c
0.6m(2')
0.6m(2')
0.15m(6")
TGL 9-20
DGL, TGL 25-30
Insert the
drainage adapter
from the inside of
the outdoor unit
Insert the
drainage adapter
from the outside of
the outdoor unit
TGL - 51302613575
50Hz TAC 505 TAC 506 0600