background image

Copyright ©2020 Delos Living LLC. All rights reserved.

PORTABLE AIR CLEANER

INTELLIPURE 950P

POWERED BY

Summary of Contents for Delos Intellipure 950P

Page 1: ...Copyright 2020 Delos Living LLC All rights reserved PORTABLE AIR CLEANER INTELLIPURE 950P POWERED BY ...

Page 2: ...FM 750 CFM 950 CFM 220 50 60 1 510 m3 hr 300 CFM 850 m3 hr 1274 m3 hr 1614 m3 hr 950 CFM 1614 m3 hr 500 CFM 850 m3 hr 750 CFM 1274 m3 hr Delos Living LLC is a reseller not the manufacturer of the products Products are manufactured by Healthway Home Products Inc Efficient purification for large spaces 12 gauge marine grade aluminum construction Butterfly latch door for easy maintenance access High ...

Page 3: ...Operation Manual Intellipure 950P COMMERCIAL PORTABLE AIR PURIFICATION SYSTEM ...

Page 4: ......

Page 5: ...althway com Limited Warranty 4 Safety Precautions 5 Receiving and Unpacking 5 Receiving Storage System Overview 6 Unit Description Component Description Installation Procedures 7 Power Requirements Location Determination System Operation 8 Maintenance 10 13 Prefilter Replacement V Bank Main Filter Replacement Cleaning the Unit Parts List Troubleshooting 14 System Schematic 15 ...

Page 6: ... way B THIS LIMITED WARRANTY DOES NOT APPLY TO SHIPPING CHARGES FOR PRODUCT SHIPPED TO OR FROM THE FACTORY OR DESIGNATED SERVICE CENTER IN CONNECTION WITH WARRANTY CLAIMS NOR DOES IT APPLY TO ANY DAMAGES OCCURRING DURING SUCH SHIPMENT C This Limited Warranty does not apply to labor for installation removal re installation and or travel or ship ping expenses and related expenses This Limited Warran...

Page 7: ... are shipped as fully assembled filter units STORAGE Store it in a dry place protected against moisture dust physical damage weather corrosion and excessive heat Must install the Prefilter andV Bank Main Filter before turning on the unit Safety Precautions This symbol will be used throughout this manual to indicate safety checkpoints Failure to heed these warnings and notices may result in damage ...

Page 8: ...l V Bank once a year DFS V Bank Main Filter 99 99 Efficient down to 007 microns once a year UNIT DESCRIPTION The Air Cleaning System is a high performance system that utilizes patented award winning Disinfecting Fil tration System technology DFS technology electrically converts a low efficiency high flow low pressure drop filter to high efficiency while retaining the low pressure drop and longer l...

Page 9: ...top grill cover Do not place the air purifier where drapes or other objects block airflow For best performance it is recommended to place the air purifier at least two 2 feet from walls and other obstructions Always lock both casters Place the unit on a flat and level surface to allow continuous airflow to the bottom intake and out the top outlet grill Do not run power cord under carpeting or near...

Page 10: ...e filter indicator g 1 Main filter indicator g 2 Change main filter indicator h 1 VOC post filter indicator h 2 Change VOC post filter indicator i 1 DFS indicator i 2 DFS deactivation indicator Disconnect power to the unit before servicing Moving Parts inside Wait 30 seconds after turning the unit off before opening the Filter Access Door The touch control technology is designed to operate under m...

Page 11: ...n and Sleep Mode Button are lit The unit will remain running at the speed set before Sleep Mode was activated 3 To deactivate Sleep Mode touch anywhere in the speed bar TURBO MODE 1 Touch Turbo Mode button to activate Turbo Mode 2 When activated all buttons on the On board Touch Pad are illuminated white 3 To deactivate Turbo Mode touch anywhere in the speed bar FILTER INDICATOR 1 2 3 1 When unit ...

Page 12: ...n accordance with the direction of the air flow label fig 3 Ensure the Prefilter is firmly seated unit will not turn on without installing Prefilter correctly Return the filter access door to the unit fig 4 threaded pin shall be positioned into the hole of the control panel to activate safety switch Failing to that will not turn on the unit When replacing filters use only HealthWay certified filte...

Page 13: ...ce the V Bank Main Filter fig 9 and apply High Energy Grid to the new filter Secure the High Energy Grid to the new V Bank Main Filter by turning and locking three panel clips fig 8 Slide theV Bank Main Filter and HighEnergyGrid Assemblybackintotheunit Pay attention to the Flow Direction Arrow on the filter the arrow should point towards the Supply Outlet end of the unit LockV bank filter with a f...

Page 14: ... that any contaminant that falls to the bottom of the filter unit is removed In extreme cases it may be necessary to remove the wires from the springs attached at each end to the power distribution bars thus allowing complete access to the inside of the High Energy Grid assembly for cleaning as previously described It is recommended that the manufacturer be contacted for detailed instructions shou...

Page 15: ...MI Filter w Fuse 5amp NZ 033 Interlock Switch Single Pole 2069 Interlock Switch Two Pole 2009 High Energy Wire WH502 Tungsten wire WH611 Optional Part Number 950 P VOC Filter Assembly 950P VOC 1200 VB VOC 1200 VB VOC PARTS LIST HealthWay recommends that the following spare parts be available on site at all times Order all parts by contacting Phone No 315 298 2904 1 800 843 3860 Fax No 315 298 6992...

Page 16: ...tly fig 6 e Ensure High Energy Wire is connected fig 5 2 The unit turns ON but no air blows out Turn off unit and unplug the power wait 2 minutes and restart the unit 3 Unit is ON but no change in speed Call Intellipure Customer Service further examination by trained technician 4 Pre filter indicator is out and Change pre filter indicator is illuminated in red Pre filter needs to be replaced Page ...

Page 17: ...Intellipure 950P 15 ...

Page 18: ...intellipure com ...

Reviews: