Infortrend
D-4
Temperature Detected (_._C )
[3f22] Peripheral Device ALERT: Controller FAN _ Not Present or Failure
Detected
[3f22] Peripheral Device ALERT: Controller FAN _ <high/low threshold>
Speed Detected (_RPM)
[3f21] Peripheral Device ALERT: +3.3V <upper/lower threshold> Voltage
Detected (_)
[3f21] Peripheral Device ALERT: +5V <upper/lower threshold> Voltage
Detected (_)
[3f21] Peripheral Device ALERT: +12V <upper/lower threshold> Voltage
Detected (_)
I
2
C Device:
[3f23] Peripheral Device ALERT: Temperature Sensor _ Failure Detected
[3f23] Peripheral Device ALERT: Temperature Sensor _ Not Present
[3f23] Peripheral Device ALERT: <high/low threshold> Temperature _
Detected (_(F/C))
[3f22] Peripheral Device ALERT: FAN _ Failure Detected
[3f22] Peripheral Device ALERT: FAN _ Not Present
[3f22] Peripheral Device ALERT: <high/low threshold> FAN _ Speed Detected
(_ RPM)
[3f21] Peripheral Device ALERT: Power Supply _ Failure Detected
[3f21] Peripheral Device ALERT: Power Supply _ Not Present
[3f21] Peripheral Device ALERT: <high/low threshold> Power Supply _
Voltage Detected (_)
[3f24] Peripheral Device ALERT: UPS _ AC Power Failure Detected
[3f24] Peripheral Device ALERT: UPS _ Battery Failure Detected
SES Devices:
[3f21] SES (C_ I_) Power Supply _: <Vendor descriptor strings/Device Not
Supported>!
[3f21] SES (C_ I_) Power Supply _: <Vendor descriptor strings/Device Not
Installed>!
[3f21] SES (C_ I_) Power Supply _: <Vendor descriptor strings/Device
Unknown Status>!
[3f21] SES (C_ I_) Power Supply _: <Vendor descriptor strings/Device Not
Available>!
[3f22] SES (C_ I_) Cooling element _: <Vendor descriptor strings/Device Not
Supported>!
[3f22] SES (C_ I_) Cooling element _: <Vendor descriptor strings/Device Not
installed>!
[3f22] SES (C_ I_) Cooling element _: <Vendor descriptor strings/Device
Unknown Status>!
[3f22] SES (C_ I_) Cooling element _: <Vendor descriptor strings/Device Not
Available>!
[3f23] SES (C_ I_) Temperature Sensor _: <Vendor descriptor strings/Device
Not Supported>!
[3f23] SES (C_ I_) Temperature Sensor _: <Vendor descriptor strings/Device
Not installed>!
[3f23] SES (C_ I_) Temperature Sensor _: <Vendor descriptor strings/Device
Содержание External RAID Controller & Subsystem Infortrend
Страница 231: ...Infortrend 10 18 operating in write back mode it is recommended to install a battery module to each controller...
Страница 249: ...Infortrend 11 2 LN SB FL NAME Disk reserved space Partition Information LG Partition Size MB LG Partition Size MB...
Страница 276: ...Array Expansion 12 17 Drive E now has a capacity of about 25GB...
Страница 327: ...Event Messages D 27...