Terminal Operation
7-44
SCSI Drive Read/Write Test
From the “View and Edit SCSI Drives” menu, select a new or used
drive that the utility is to perform on; then press [
ENTER
]. Select
“SCSI Drive Utilities," then press [
ENTER
]. Choose “Read/Write
Test” and press [
ENTER
]. You can choose to enable/disable the
following options:
1.
Auto Reassign Bad Block;
2.
Abort When Error Occurs;
3.
Drive Test for - Read Only/Read and Write.
When finished with configuration, select "Execute Drive Testing"
and press
[ENTER]
to proceed.
The Read/Write test progress will be indicated by a status bar.
You may press
[ESC]
and select "Read/Write Test" later and choose
either to "View Read/Write Testing Progress" or to "List Current
Bad Block Table." If you want to stop testing the drive, select
"Abort Drive Testing" and press
[ENTER]
to proceed.