Fibre Operation
8-5
Drive IDs:
Supported ways to address a Fibre port include Hard assigned and
Soft assigned. The controller supports automatic loop ID
assignment on drive channels. A hard loop address ID can be
assigned to disk drives by enclosure jumper setting. If the AL_PA
configuration on drive enclosure has been set to a neutral status,
physical IDs will be automatically assigned to drives.
In-band Fibre and S.E.S. Support:
"SCSI Pass-through" commands are supported over host and drive
loops just as they are over SCSI channels. The "in-band Fibre"
protocol for packaging "External Interface" protocol
commands/responses is supported over host Fibre loops (such as
the RAIDWatch Manager). Drive-side S.E.S. device identification,
monitoring and control are likewise supported over drive loops.
Содержание External RAID Controller & Subsystem Infortrend
Страница 231: ...Infortrend 10 18 operating in write back mode it is recommended to install a battery module to each controller...
Страница 249: ...Infortrend 11 2 LN SB FL NAME Disk reserved space Partition Information LG Partition Size MB LG Partition Size MB...
Страница 276: ...Array Expansion 12 17 Drive E now has a capacity of about 25GB...
Страница 327: ...Event Messages D 27...