Infortrend
10-28
Choose "Redundant Controller [Function]," and then press
[ENTER]
. (Note:
The current setting will be displayed on the screen. If this controller has
never been set as a redundant controller before, the default setting is
"Disabled". The message "Redundant Controller - Disabled" will be
displayed on the screen. Press
[ENTER]
to proceed.)
The message "Enable Redundant Controller in Autoconfigure Mode" will
appear. Use the arrow keys to scroll through the available options
("Primary," "Secondary," or "Autoconfigure"). Press
[ENTER]
on "Primary."
•
Power off controller 1, then power on controller 2. Set controller 2 to
"Secondary" as described above.
•
Power off controller 2.
•
Power on drives, both controllers, and host computer(s) for the settings
to take effect.
•
The Primary and Secondary controllers synchronize each other’s
configurations at frequent intervals through the established
communications path(s). Write-back cache will be disabled if no sync.
cache path exists.
•
Select "View and Edit SCSI Channels" from the Main Menu, the
communications path will be displayed as "RCCOM (Redundant
Controller Communications)."