Infortrend
9-21
controller to keep waiting for a drive, and it may sometimes cause a
host timeout.
Choose “SCSI I/O Timeout –Default (7 seconds),” then press
[ENTER]
. A list of selections will appear. Move cursor bar to a
selection, then press
[ENTER]
. Choose
Yes
in the dialog box that
follows to confirm the setting.
Maximum Tag Count (Tag Command Queuing)
The controller supports tag command queuing with an adjustable
maximum tag count from 1 to 128. The default setting is “Enabled”
with a maximum tag count of 32. Choose “Maximum Tag Count”,
then press
[ENTER]
. A list of available tag count numbers displays.
Move cursor bar to a number, then press
[ENTER]
. Choose
Yes
in
the dialog box that follows to confirm the setting.
IMPORTANT!
•
Every time you change this setting, you must reset the controller for the
changes to take effect.
•
Disabling Tag Command Queuing will disable hard drives’ built-in cache
for Write-Back operation.