Redundant Controller
10-33
Forcing Controller Failover for Testing
This function is reserved for de-bugging.
Testing the failover functionality can be performed using the following
methods.
1.
Pulling out one of the controllers to simulate controller
failure
Pull out either the primary or the secondary controller
An error message will display immediately with sounded alarm. The
existing controller takes over the workload within a second. Clear all
errors by pressing the
ESC
key. You may now install the controller once
removed after all activities have been taken over by the existing
controller. It may take a while for the controllers to finish re-
initialization and assuming their load.
2.
Failover by "Forcing controller failure"
Select "View and Edit Peripheral Devices," "Set Peripheral Device Entry,"
and "Redundant Controller Primary/Secondary."
Select "Force Primary/ Secondary Controller Failure." You may now
pull out the controller you had just disabled. I/Os should be continued
by the existing controller. Continue the aforementioned procedure to
complete the test.
WARNING!
•
This function should only be performed for testing the redundant controller
functionality before any critical data is committed to drives. Although the controller
is designed to be hot-swappable, unpredictable failures may occur during the process,
i.e. improper handling of PCB boards while replacing the controller.
Содержание External RAID Controller & Subsystem Infortrend
Страница 231: ...Infortrend 10 18 operating in write back mode it is recommended to install a battery module to each controller...
Страница 249: ...Infortrend 11 2 LN SB FL NAME Disk reserved space Partition Information LG Partition Size MB LG Partition Size MB...
Страница 276: ...Array Expansion 12 17 Drive E now has a capacity of about 25GB...
Страница 327: ...Event Messages D 27...