Infortrend
5-15
Adding a Global Spare Drive
Press
ENT
for two seconds to enter the
Main Menu. Press
▼
or
▲
to select
"View and Edit SCSI Drives," then
press
ENT
.
SCSI drive information will be
displayed on the LCD. Press
▼
or
▲
to
select a SCSI drive that has not been
assigned to any logical drive yet, then
press
ENT
.
Press
▼
or
▲
to select “Add Global
Spare Drive,” then press
ENT
.
Press
ENT
again for two seconds to
add the spare drive. The message
“Add Global Spare Drive Successful”
will be displayed on the LCD.
Rebuild Settings
Press
ENT
for two seconds to enter the
Main Menu. Press
▼
or
▲
to select
"View and Edit Config Parms," then
press
ENT
.
Press
▼
or
▲
to select “Disk Array
Parameters,” then press
ENT
.
Press
▼
or
▲
to select “Rebuild
Priority Low,” then press
ENT
. “Low”
refers to the temporary setting.
Press
ENT
again and the abbreviation
mark “..” will change to question mark
“?”. Press
▼
or
▲
to select priority
“Low,” “Normal,” “Improved,” or
“High”.
Press
ENT
to confirm and the question
mark “?” will turn into “
..
”.
View and Edit
SCSI Drives
↕
C=2 I=4 1010MB
NEW DRV SEAGATE
Add Global Spare
Drive ..
Add Global Spare
Drive Successful
View and Edit
Config Parms
↕
Disk Array
Parameters..
Rebuild Priority
Low ..
Rebuild Priority
Low ?
Rebuild Priority
High ..
Содержание External RAID Controller & Subsystem Infortrend
Страница 231: ...Infortrend 10 18 operating in write back mode it is recommended to install a battery module to each controller...
Страница 249: ...Infortrend 11 2 LN SB FL NAME Disk reserved space Partition Information LG Partition Size MB LG Partition Size MB...
Страница 276: ...Array Expansion 12 17 Drive E now has a capacity of about 25GB...
Страница 327: ...Event Messages D 27...