Fibre Operation
8-13
2.
Communications Traffic Distributed over All Drive
Loops
: Select all drive loops and configure them as "Drive
+ RCCOM (Drive Loops plus Redundant Controller
Communications)." The communications traffic between
the two controllers will be automatically distributed over
all drive loops.
!
As displayed above, channel(s) selected as the
communications paths will be displayed as "channel
number (C: connected)" or "channel number (D:
disconnected)." If channels configured in a dual-loop are
selected, channel status will be displayed as "channel
number (pair loop; C or D)."
!
If any of the communications loops should fail, the inter-
controller traffic will be automatically shifted to the
remaining Drive/RCC loop(s).
Содержание External RAID Controller & Subsystem Infortrend
Страница 231: ...Infortrend 10 18 operating in write back mode it is recommended to install a battery module to each controller...
Страница 249: ...Infortrend 11 2 LN SB FL NAME Disk reserved space Partition Information LG Partition Size MB LG Partition Size MB...
Страница 276: ...Array Expansion 12 17 Drive E now has a capacity of about 25GB...
Страница 327: ...Event Messages D 27...