Infortrend
C-2
will hand over the workload and then reset itself for the new
firmware to take effect. The rolling upgrade is automatically
performed by controller firmware and user's intervention is not
necessary.
Redundant Controller Firmware Sync-version:
A controller used to replace a failed unit in a dual-controller
system is often running a newer release of firmware version. To
solve the contention, firmware running on the replacement
controller will be downgraded to that running on the surviving
controller.
IMPORTANT!
•
Allow the downloading process to finish. Do not reset or turn off the
computer or the controller while it is downloading the file. Doing so
may result in an unrecoverable error that requires the service of the
manufacturer.
•
While the firmware is new, the boot record that comes with it may be the
same version as the one in the controller. If this is the case, there is no
need to upgrade the Boot Record Binary.
NOTE:
•
Controller serial port COM 2can not be used to download firmware.
Upgrading Firmware Using In-band SCSI +
RAIDWatch Manager
Establish the In-band SCSI connection in RAIDWatch Manager
Please refer to RAIDWatch
User's Manual
for details on
establishing the In-band SCSI connection for RAIDWatch
Manager.
Содержание External RAID Controller & Subsystem Infortrend
Страница 231: ...Infortrend 10 18 operating in write back mode it is recommended to install a battery module to each controller...
Страница 249: ...Infortrend 11 2 LN SB FL NAME Disk reserved space Partition Information LG Partition Size MB LG Partition Size MB...
Страница 276: ...Array Expansion 12 17 Drive E now has a capacity of about 25GB...
Страница 327: ...Event Messages D 27...