Advanced Configurations
9-22
Detection of Drive Hot Swap Followed by Auto
Rebuild
Choose “Periodic Auto-Detect Failure Drive Swap Check Time”;
then press
[ENTER]
. Move the cursor to the desired interval; then
press
[ENTER]
. Choose
Yes
in the dialog box that follows to
confirm the setting.
The controller scans drive buses at this interval to check if a failed
drive has been replaced. If a failed drive is replaced, the controller
will proceed with the rebuild process.
SAF-TE and S.E.S. Enclosure Monitoring
If there are remote devices in your RAID enclosure being monitored
via SAF-TE/S.E.S., use this function to decide at what interval the
controller will check the status of these devices. Choose “Periodic
SAF-TE and SES Device Check Time”; then press
[ENTER]
. Move
the cursor to the desired interval; then press
[ENTER]
. Choose
Yes
in the dialog box that follows to confirm the setting.
Periodic Drive Check Time
The “Periodic Drive Check Time” is the time interval for the
controller to check all disk drives that were on the SCSI bus at
controller startup (a list of all the drives that were detected can be
seen under “View and Edit SCSI Drives”).
The default value is “Disabled.” “Disabled” means that if a drive is
removed from the bus, the controller will not be able to know – so
Содержание External RAID Controller & Subsystem Infortrend
Страница 231: ...Infortrend 10 18 operating in write back mode it is recommended to install a battery module to each controller...
Страница 249: ...Infortrend 11 2 LN SB FL NAME Disk reserved space Partition Information LG Partition Size MB LG Partition Size MB...
Страница 276: ...Array Expansion 12 17 Drive E now has a capacity of about 25GB...
Страница 327: ...Event Messages D 27...