Front Panel Operation
5-24
An empty drive entry is added for this
channel/SCSI ID for enclosure
management. The drive status is
“ABSENT.”
To clear the empty drive entry, press
ENT
and use arrow keys to select
“Clear Drive Status,” then press
ENT
to proceed.
Press
ENT
for two seconds to confirm
the drive entry’s deletion. Information
of other drives will be displayed
instead.
Identifying a Drive
Press
ENT
for two seconds to enter the
Main Menu. Press
▼
or
▲
to select
"View and Edit SCSI Drives," then
press
ENT
.
SCSI drive information will be
displayed. Press
▼
or
▲
to select a
SCSI drive, then press
ENT.
Press
▼
or
▲
to select “Identify Drive,”
then press
ENT
to continue.
Press
▼
or
▲
to select “Flash All
Drives”, “Flash Selected Drive”, or
“Flash All But Selected Drive”. Press
ENT
for two seconds to flash the
read/write LEDs of all the connected
drives.
Or, press
▼
or
▲
to select “Flash
Selected SCSI Drives," then press
ENT
for two seconds to flash the read/write
LED of the selected drive. The
read/write LED will light for a
configurable time period from 1 to 999
seconds.
View and Edit
SCSI Drives
↕
C=1 I=0 1010MB
GlobalSB SEAGATE
Flash All
Drives ?
Flash Selected
SCSI Drives ?
Identify Drive
..
C=1 I=1 ABSENT
Clear Drive
Status ..
Clear Drive
Status ?
Flash all But
Selected Drives?
Содержание External RAID Controller & Subsystem Infortrend
Страница 231: ...Infortrend 10 18 operating in write back mode it is recommended to install a battery module to each controller...
Страница 249: ...Infortrend 11 2 LN SB FL NAME Disk reserved space Partition Information LG Partition Size MB LG Partition Size MB...
Страница 276: ...Array Expansion 12 17 Drive E now has a capacity of about 25GB...
Страница 327: ...Event Messages D 27...