Event Messages
D-7
Controller Event
Alert:
2-Line LCD
DRAM Parity Error Detected
Terminal
[0104] Controller ALERT: DRAM Parity Error Detected
Event Type
!
Alert
"
Warning
"
Notification
What
Happens?
A DRAM parity error encountered.
What to
Do?
Contact your RAID system supplier and replace with new module(s) if
necessary.
2-Line LCD
DRAM Parity Error Detected
Terminal
[0105] Controller <primary/secondary> SDRAM ECC <multi-
bits/single-bit> Error Detected
Event Type
!
Alert
"
Warning
"
Notification
What
Happens?
A DRAM ECC detected error encountered.
What to
Do?
Contact your RAID system supplier and replace with new module(s) if
necessary.?
2-Line LCD
CHL:_ FATAL ERROR (_)
Terminal
[0110] CHL:_ FATAL ERROR (_)
Event Type
!
Alert
"
Warning
"
Notification
What
Happens?
One channel has failed.
What to
Do?
Check if cable connectors are firmly seated and SCSI buses are
properly terminated. With Fibre channels, disconnection may happen
on the host side, hub or switch, etc. In redundant mode, the
counterpart controller will take over and you may ask your system
provider to remove the controller with a failed channel for a repair.
2-Line LCD
Redundant Ctlr Failure Detected
Terminal
[0111] Controller ALERT: Redundant Controller Failure Detected
Event Type
!
Alert
"
Warning
"
Notification
What
Happens?
One of the RAID controllers has failed.
What to
Do?
Contact your RAID system supplier for a replacement controller.
2-Line LCD
Redundant Ctlr Failure Detected
Terminal
[0111] Controller NOTICE: Redundant Controller Firmware Updated
Event Type
"
Alert
"
Warning
!
Notification
What
Happens?
RAID controllers have finished shifting I/Os, resetting, and have come
online with new version of firmware.
What to
Do?
Содержание External RAID Controller & Subsystem Infortrend
Страница 231: ...Infortrend 10 18 operating in write back mode it is recommended to install a battery module to each controller...
Страница 249: ...Infortrend 11 2 LN SB FL NAME Disk reserved space Partition Information LG Partition Size MB LG Partition Size MB...
Страница 276: ...Array Expansion 12 17 Drive E now has a capacity of about 25GB...