Infortrend
5-41
SCSI Drive Read/Write Test
From the “View and Edit SCSI Drives”
menu, select a new or used drive that
the utility is to be performed on; then
press
ENT
. Select “SCSI Drive
Utilities;" then press
ENT
. Choose
“Read/Write Test” and press
ENT
.
Press
▼
or
▲
to select and choose to
enable/disable the following options:
1.
"Auto Reassign Bad Block;
2.
Abort When Error Occurs;
3.
Drive Test for - Read Only/Read
and Write.
When finished with configuration,
select "Execute Drive Testing" and
press
ENT
to proceed.
The Read/Write test progress will be
indicated as a percentage.
You may press
ESC
and select
"Read/Write Test" later and press
▼
or
▲
to select to "View Read/Write
Testing Progress" or to "List Current
Bad Block Table." If you want to stop
testing the drive, select "Abort Drive
Testing" and press
ENT
to proceed.
Drive Read/Write
Test ..
Auto Reassign
Disabled ..
Abort When Error
Occur-Enabled
Drive Test for
Read and Write..
Execute Drive
Testing ..
Drv Testing 23%
Please Wait !
View Read/Write
Test Progress ..
List Current
Bad Block Table.
Abort Read/Write
Testing ..
Содержание External RAID Controller & Subsystem Infortrend
Страница 231: ...Infortrend 10 18 operating in write back mode it is recommended to install a battery module to each controller...
Страница 249: ...Infortrend 11 2 LN SB FL NAME Disk reserved space Partition Information LG Partition Size MB LG Partition Size MB...
Страница 276: ...Array Expansion 12 17 Drive E now has a capacity of about 25GB...
Страница 327: ...Event Messages D 27...