Infortrend
D-10
Drive SCSI Channel/Drive Error
Drive
Warning:
2-Line LCD
C:_ I:_ SCSI Target ALERT
Terminal
[1101] CHL:_ ID:_ SCSI Target ALERT: Unexpected Select Timeout
Event Type
"
Alert
!
Warning
"
Notification
What
Happens?
Drive SCSI target select timeout. The specified hard drive cannot be
selected by the controller. Whether the drive has been removed, or the
cabling/termination/canister is out of order.
What to
Do?
Check drive-side SCSI cable/termination and drive canister
connections.
2-Line LCD
C:_ I:_ SCSI Target ALERT: Gross Phase/Signal Error Detected
Terminal
[1102] CHL:_ ID:_ SCSI Target ALERT: Gross Phase/Signal Error
Detected
Event Type
"
Alert
!
Warning
"
Notification
What
Happens?
Drive-side SCSI phase/signal abnormality detected.
What to
Do?
Press <ESC> to clear the message.
2-Line LCD
C:_ I:_ SCSI Target ALERT: Unexpected Disconnect Encountered
Terminal
[1103] CHL:_ I:_ SCSI Target ALERT: Unexpected Disconnect
Encountered
Event Type
"
Alert
!
Warning
"
Notification
What
Happens?
Drive-side SCSI target unexpected disconnect detected.
What to
Do?
Check cabling/termination and canister connections.
2-Line LCD
C:_ I:_ SCSI Drive ALERT: Negotiation Error Detected
Terminal
[1104] CHL:_ ID:_ SCSI Drive ALERT: Negotiation Error Detected
Event Type
"
Alert
!
Warning
"
Notification
What
Happens?
Drive-side SCSI target sync/wide negotiation abnormality detected.
What to
Do?
Содержание External RAID Controller & Subsystem Infortrend
Страница 231: ...Infortrend 10 18 operating in write back mode it is recommended to install a battery module to each controller...
Страница 249: ...Infortrend 11 2 LN SB FL NAME Disk reserved space Partition Information LG Partition Size MB LG Partition Size MB...
Страница 276: ...Array Expansion 12 17 Drive E now has a capacity of about 25GB...
Страница 327: ...Event Messages D 27...