Infortrend
6-2
6.2
Main Menu
Use the arrow keys to move the cursor bar through the menu items, then press
[ENTER]
to choose a menu, or
[ESC]
to return to the previous menu/screen.
In a subsystem or controller head where battery status can be detected, battery
status will be displayed at the top center. Status will be stated as Good, Bad, or
several “+ ” (plus) marks will be used to indicate battery charge. A battery
fully-charged will be indicated by five plus mark.
When initializing or scanning an array, the controller displays progress
percentage on the upper left corner of the configuration screen. “i” indicates
array initialization. “s” stands for scanning process. The following number
indicates logical drive number.
6.3
Quick Installation
Type
Q
or use the
↑↑↑↑
↓↓↓↓
keys to select "Quick installation", then press
[ENTER]
.
Choose
Yes
to create a logical drive.
All possible RAID levels will be displayed. Use the
↑↑↑↑
↓↓↓↓
keys to select a RAID
level, then press
[ENTER]
. The assigned spare drive will be a Local Spare Drive,
not a Global Spare Drive.