Infortrend
5-31
Press
▼
or
▲
to select “View and Edit
SCSI Target,” then press
ENT
.
Press
▼
or
▲
to select a SCSI target,
then press
ENT
.
Slot Number
To set the Slot number of the SCSI
target, choose “Slot Assignment," then
press
ENT
. The current slot number
will be displayed.
Press
▼
or
▲
to change the slot
number, then press
ENT
for two
seconds.
Maximum Synchronous Transfer Clock
Press
▼
or
▲
to select a SCSI target,
then press
ENT
.
To set the maximum synchronous
clock of this SCSI target, choose “Max.
Synchronous Xfer Clock," then press
ENT
. The current clock setting will be
displayed on the LCD.
Press
▼
or
▲
to change the clock, then
press
ENT
for two seconds.
Maximum Transfer Width
Press
▼
or
▲
to select a SCSI target,
then press
ENT
.
To set the maximum transfer width of
this SCSI target, choose “Max. Xfer
Narrow Only” or “Max. Xfer Wide
Supported,” then press
ENT
. The
SCSI Target
CHL=1 ID=0 ..
SCSI Target
CHL=1 ID=0 ..
SCSI Target
CHL=1 ID=0 ..
Slot Assignment
Default No Set..
Max Synchronous
Xfer Clock# 12..
Max Xfer Wide
Supported ..
Slot Assignment
Set to # 9 ?
Period Factor
Def= 12 to --?
Содержание External RAID Controller & Subsystem Infortrend
Страница 231: ...Infortrend 10 18 operating in write back mode it is recommended to install a battery module to each controller...
Страница 249: ...Infortrend 11 2 LN SB FL NAME Disk reserved space Partition Information LG Partition Size MB LG Partition Size MB...
Страница 276: ...Array Expansion 12 17 Drive E now has a capacity of about 25GB...
Страница 327: ...Event Messages D 27...