84
◢
When the torque control, motor speed limit in this
parameter range. There was a phenomenon of speeding can prevent the light load. Speeding, speed
control to reduce the actual torque intervention, but the actual speed will be slightly error.
number
name
value range
the
default value
unit
apply
Pn199
Source of limited torque
control speed choice
0~2
0
T
◢
Pn199=0
Restricted by Pn198 parameters
Pn199=1
Restricted by internal speed instruction 1 ~ 8
Pn199=2:
If Pn204 = 1, i.e., all instructions from the internal torque, torque, speed can be restricted by analog voltage
speed command
◢
All the above speed limit both positive and negative, multipl e speed limit, restricted to the minimum speed.
◢
If this parameter is set to 1, restricted by internal speed instruction, by sp1, sp2, sp3 limited decision speed value:
SP3 SP2 SP1
Speed instruction
0
0
0
Internal speed 1
0
0
1
Internal speed 2
0
1
0
Internal speed 3
0
1
1
Internal speed 4
1
0
0
Internal speed 5
1
0
1
Internal speed 6
1
1
0
Internal speed 7
1
1
1
Internal speed 8
1 0 means OFF, 1 is
ON.
◢
Even if the setting values than the system allows the highest speed, the actual speed can limit under the highest speed.
number
name
value
range
the
default value
unit
apply
Pn200
The internal torque 1
-300~300
0
%
T