123
consumption of renewable power, can produce high temperature above 100 ° C, please be careful, the
connection of regenerative resistor wire please use of heat-resistant non-flammable cables, and confirm the
regenerative resistor without touching anything.
注意:使用再生电阻时如果有上述报警产生,请切断电源,冷却半小时。由于再生晶
体管发生故障,再生电阻异常发热,可能会造成火灾。请务必根据应用场合,选择相匹
配的制动电阻。
Note: if the alarm when using regenerative resistor, please cut off power supply, cooling and
a half hours. Due to the regenerative transistor failure, abnormal regeneration resistance heating, may cause a
fire. Please be sure to choose according to applications, matching the braking resistor.
附录
F
原点回归
Appendix F origin point
F.1
原点回归运行步骤
F. 1 origin point operation steps
1
:找参考点
Looking for a reference point
启动原点回归功能后,按原点加归第一速度寻找参考点,可使用
SigIn
输入端子
REF
、
CCWL
或
CWL
作为参考点,也可以
Z
脉冲作为参考点,可选择正转或反转方向寻
找
。
After start origin regression function, looking for reference point at the origin and return to the first rate,
can use SigIn input terminals REF, CCWL or.cwl as a reference point, can also be Z pulse as a reference point,
can choose forward or reverse direction finding.
2
:找原点
find the origin
当找到参考点后,再以第二速度寻找原点,可选择继续向前或向后折返找
Z
脉冲,
也可以直接以参考点作原点。
When find reference point, and then to find the origin at the second speed,
can choose continue to forward or backward turn-back find Z pulse, may also directly to the reference point for
the origin.
原点回归执行过程中,为避免速度剧烈变化造成的机械冲击,可设置参数
Pn040
、
Pn041
进行加减速。找到的原点加上偏移量脉冲作为实际原点,偏移量为:
Pn036*10000+Pn037
。
Origin point execution process, to avoid rapid changes of mechanical impact velocity, can be set parameters for
deceleration Pn040, Pn041. Find the origin and offset pulse as actual origin, the offset is:
Pn036*10000+Pn037
。
原点回归参考点模式
(Pn034)
和原点模式(
Pn035
)有以下组合:
The origin return reference point
mode (Pn034) and the origin (Pn035) has the following combination: