85
Pn201
The internal torque 2
-300~300
0
%
T
Pn202
The internal torque 3
-300~300
0
%
T
Pn203
The internal torque 4
-300~300
0
%
T
◢
Select the internal torque control mode, use input port of the SigIn TR1 TR2 can choose 4 kinds of torque command:
TR2 TR1
Torque command
0
0
The external torque 1 or internal analog torque instruction (decided by Pn204)
0
1
The external torque 2
1
0
The external torque 3
1
1
The external torque 4
NOTE:
1 0 means OFF, 1 is
ON.
Note 2: if the SigIn port doesn't specify TR2, TR1 functions, is OFF by default.
number
name
value range
the
default value
unit
apply
Pn204
Torque command source
0~1
0
T
0: external analog torque command
1:1internal torque 1
number
name
value range
the
default value
unit
apply
Pn205
D shaft torque regulator proportional gain
5~2000
100
%
All
Pn206
D shaft torque regulator integral time
constant
5~2000
100
%
All
◢
Space vector modulation, D shaft torque regulator proportional gain and integral time constant.
number
name
value range
the
default value
unit
apply
Pn207
Speed feedback adjustment coefficient
1~3000
100
T