96
voltage, if the difference is too big, the
internal components damaged, replace the
servo amplifier.
3
In a reasonable range, appropriate
reduction small load inertia or prolonged
deceleration, or need additional braking
resistor.
AL-04
power on
Intelligent power
module directly produce
the report to the alarm
1
Check the motor line U, V, W and
encoder line is normal.
2
Turn the power off half an
hour, electricity again, if the alarm is still
there, may be internal power module is
damaged, please replace the servo
amplifier.
3:
Speed loop and current loop pid p
arameter Settings.
AL-05
reset
overload 1
Pn014 parameters set period of time for
greater than Pn012 overload capacity
parameters or Pn013 set by multiples of the
current.
1
Check the
motor line U, V, W and
encoder line is normal.
2:
Motor high frequency,
acceleration and deceleration delay when
the director of the deceleration time, reduce
the load inertia, or in more powerful capacity