60
◢
When using the Modbus communication, drive in each group should be set in advance different sites; If
repeat setting site, will lead to paralysis of communication
number
name
value
range
the
default value
unit
apply
Pn066
▲
Communication
baud rate
0-3
1
All
◢
0
:
4800
◢
1
:
9600
◢
2
:
19200
◢
3
:
38400
number
name
value range
the
default value
unit
apply
Pn067
▲
Communication mode setting
0-8
8
All
◢
Parameter values are defined as follows table, see chapter 7 of the Modbus communication function
set
instructions
0
7 , N , 2 ( Modbus ,ASCII )
1
7 , E , 1 ( Modbus , ASCII )
2
7 , O , 1 ( Modbus , ASCII )
3
8 , N , 2 ( Modbus , ASCII )
4
8 , E , 1 ( Modbus , ASCII )
5
8 , O , 1 ( Modbus , ASCII )
6
8 , N , 2 ( Modbus , RTU )
7
8 , E , 1 ( Modbus , RTU )
8
8 , O , 1 ( Modbus , RTU )
number
value range
the
default value
unit
apply
Pn068
Choose to register 1 input
function control way
0~32767
0
All
Pn069
Choose to register 2
input
0~4095
0
All