55
number
name
value range
the
default value
unit
apply
Pn035
The origin back to the origin model
0~2
0
All
◢
1
Backward looking for Z pulse as the origin
◢
2
Forward looking for Z pulse as the origin
◢
3
Directly with reference point rise along the origin
number
name
value range
the
default value
unit
apply
Pn036
The origin position offset high
-9999~9999
0
ten
thousand pulse
All
Pn037
The origin position offset low
-9999~9999
0
pulse
All
◢
After finding the origin, plus the offset (10000 + Pn037 Pn036 *) as a real origin
number
name
value
range
the
default value
unit
apply
Pn038
The origin back to the first speed
1~3000
200
R/min
All
Pn039
The origin back to the
second
speed
1~3000
50
R/min
All
◢
,
Perform operation on the origin, looking for reference points
at the first speed, arrived at the
reference point, seeking the origin at the second rate. The second speed should be less than the first speed
number
name
value range
the
default value
unit
apply
Pn040
The accelerating time of origin
5~10000
50
ms
All
Pn041
The origin return to slow down time
5~10000
50
ms
All
◢
In the execution of origin point, motor from zero speed accelerated to the rated speed of the time, only for the origin
returning operation
name
value
the
unit