67
much, must through the regeneration way discharge, otherwise the internal voltage is too high, damage to the
drive. Set up, the longer the voltage release faster, but the greater the power needed for regenerative resistor,
otherwise easy to burn regenerative resistor. See appendix E specific Settings.
4.3.2
Position control parameters
number
name
value range
the
default value
unit
apply
Pn096
▲
The command pulse input mode
0-2
0
P
Pn097
▲
Instruction selection logic pulse
input direction
0-1
0
P
◢
Command pulse input mode in the following table:
Pn096
Forward command
reverse command
0
Pulse + direction
L
H
PP+
PP-
PD+
PD-
1
Forward/reverse pulse
PP+
PP-
PD+
PD-
L
L
2
The orthogonal pulse
PP+
PP-
PD+
PD-
◢
Pn097 = 0: input command, the motor rotate counterclockwise (CCW)
Pn097 = 1: input command, motor rotate clockwise (included)
number
name
value range
the
default value
unit
apply
Pn098
Pulse electronics gear than the
molecules of 1
1~32767
1
P
Pn099
Pulse electronics gear than the
molecules of 2
1~32767
1
P
Pn100
Pulse electronics gear than the
molecules of 3
1~32767
1
P